A battery backup system keeps critical equipment running when mains power fails. It combines rectifiers (chargers) that power the load and charge the battery, a battery bank sized for the required backup time, a controller that monitors everything, and DC distribution. Where AC loads also need backup, an inverter or Rectiverter is added. KPS designs complete battery backup systems in Egypt using Delta Eltek DC power and EnerSys batteries.

Recommended batteries: DataSafe HX+ TPPL UPS battery for data centers and UPS, and PowerSafe OPzV 2V gel battery for solar, telecom and oil & gas.

Eltek partner and authorized EnerSys distributor in Egypt · ISO 9001, 14001, 45001 and 50001 certified · 250+ projects delivered · 300+ clients served

What a battery backup system includes

Choosing the right backup system for your site

ApplicationTypical systemTypical batteries
Telecom sites (48 VDC)Flatpack2 or Flatpack S DC power systemPowerSafe SBS, V-FT or OPzV
Data centers and UPSUPS with high-rate batteries, or a 380 VDC systemDataSafe HX, HX+ or NPX
Substations and industry (110 / 220 VDC)Flatpack2 110–125V, 220V or IBB industrial systemsPowerSafe OPzS or OPzV
Sites with AC and DC loadsRectiverter systemPowerSafe SBS or OPzV
Emergency lightingCentral battery systemPowerSafe OPzV, SBS or Genesis
Off-grid and hybrid sitesSolar hybrid power systemPowerSafe OPzV, TS or PV Bloc

How backup time is sized

Battery capacity depends on the load, the required autonomy, the allowed end voltage, the battery temperature and an ageing margin. As a simple example, a 2 kW load on a 48 V system draws about 42 A, so four hours of backup needs roughly 167 Ah before design margins. KPS sizes stationary lead-acid batteries using recognised methods such as IEEE 485, adding correction factors for temperature and end-of-life capacity so the system still meets its backup time in year 10, not only on day one.

Why KPS

Battery Backup Systems: FAQs

What is a battery backup system?

A battery backup system is a rectifier (charger), a battery bank, a controller and distribution that keep critical loads powered when mains fails. An inverter or Rectiverter can be added to back up AC loads as well.

How long can a battery backup system run?

Backup time depends on the load and the battery capacity. Telecom and industrial systems are typically designed for 2 to 8 hours, data center UPS systems for 5 to 15 minutes. KPS sizes the battery for the autonomy you need, including temperature and ageing margins.

Which batteries are used in telecom battery backup systems?

Telecom sites usually use 12 V front-terminal VRLA batteries such as EnerSys PowerSafe SBS or V-FT (TPPL), or 2 V PowerSafe OPzV gel cells for long backup times.

Can one system back up both AC and DC loads?

Yes. Eltek Rectiverter systems supply 48 VDC (or 110 / 220 VDC) and backed-up 230 VAC from the same battery bank, without a separate UPS and inverter.

Does KPS install battery backup systems in Egypt?

Yes. KPS designs, supplies, installs and maintains battery backup systems across Egypt for telecom, data center, oil and gas, utility and industrial customers.