Delta ViFlow Rack PDU (Basic / Metered)

Delta ViFlow rack PDU: basic and metered rack PDUs in 1U and Zero-U formats, 16 A or 32 A, single- or three-phase, with IEC C13/C19 outlets and branch breakers.

The Delta ViFlow series covers basic and metered rack PDUs that fit any rack and install in minutes. Basic models distribute power with branch circuit breaker protection; metered models add an LED current display and an optional network module for remote monitoring. Horizontal 1U and vertical Zero-U versions are available with single- or three-phase input.

Key Features

  • Basic and metered rack PDU versions
  • Horizontal 1U and vertical Zero-U mounting
  • Plug and play with international standard plugs and IEC C13 / C19 outlets
  • Single-phase and three-phase input options
  • Tool-less installation in Delta rack cabinets, compatible with EIA and custom racks
  • Branch circuit breaker protection (overload / earth fault)
  • LED current display and optional network module (metered models)

Technical Specifications

Model Type Input Plug Outlets Size (W x H x D)
PDU7311 Basic, 1U horizontal 200–240 VAC 1-phase, 16 A IEC 309 16 A 12 x C13 440 x 44 x 55 mm
PDU5315 Basic, Zero-U vertical 200–240 VAC 1-phase, 32 A IEC 309 32 A 4 x C19, 24 x C13 48 x 1250 x 50/90 mm
PDU1311 Metered, Zero-U vertical 200–240 VAC 1-phase, 16 A IEC 309 16 A 3 x C19, 24 x C13 48 x 1250 x 50/90 mm
PDU4425 Metered, Zero-U vertical 346–415 VAC 3-phase, 32 A IEC 309 32 A 5-wire 3 x C19, 36 x C13 48 x 1660 x 50/100 mm
PDU4425-M Metered, Zero-U vertical 346–415 VAC 3-phase, 32 A IEC 309 32 A 5-wire 3 x C19, 24 x C13 48 x 1535 x 50/100 mm

Examples of CE-certified models for 230/400 V markets. More configurations are available; metered models offer RS-232 ports for an SNMP card and operate at 0–45 °C.

Applications

Server racks, network cabinets, telecom rooms and small data centers that need reliable, simple power distribution to IT equipment.

Common Questions

What is a rack PDU?
A rack PDU is a power strip designed for 19-inch racks that distributes power from the rack feed to servers, switches and storage, usually through IEC C13 and C19 outlets.

Should I choose a 1U or Zero-U PDU?
1U horizontal PDUs suit small racks with few devices; Zero-U vertical PDUs mount at the back or side of the rack, save rack space and provide more outlets.