The Delta ViFlow series covers basic and metered rack PDUs that fit any rack and install in minutes. Basic models distribute power with branch circuit breaker protection; metered models add an LED current display and an optional network module for remote monitoring. Horizontal 1U and vertical Zero-U versions are available with single- or three-phase input.
Key Features
- Basic and metered rack PDU versions
- Horizontal 1U and vertical Zero-U mounting
- Plug and play with international standard plugs and IEC C13 / C19 outlets
- Single-phase and three-phase input options
- Tool-less installation in Delta rack cabinets, compatible with EIA and custom racks
- Branch circuit breaker protection (overload / earth fault)
- LED current display and optional network module (metered models)
Technical Specifications
| Model | Type | Input | Plug | Outlets | Size (W x H x D) |
|---|---|---|---|---|---|
| PDU7311 | Basic, 1U horizontal | 200–240 VAC 1-phase, 16 A | IEC 309 16 A | 12 x C13 | 440 x 44 x 55 mm |
| PDU5315 | Basic, Zero-U vertical | 200–240 VAC 1-phase, 32 A | IEC 309 32 A | 4 x C19, 24 x C13 | 48 x 1250 x 50/90 mm |
| PDU1311 | Metered, Zero-U vertical | 200–240 VAC 1-phase, 16 A | IEC 309 16 A | 3 x C19, 24 x C13 | 48 x 1250 x 50/90 mm |
| PDU4425 | Metered, Zero-U vertical | 346–415 VAC 3-phase, 32 A | IEC 309 32 A 5-wire | 3 x C19, 36 x C13 | 48 x 1660 x 50/100 mm |
| PDU4425-M | Metered, Zero-U vertical | 346–415 VAC 3-phase, 32 A | IEC 309 32 A 5-wire | 3 x C19, 24 x C13 | 48 x 1535 x 50/100 mm |
Examples of CE-certified models for 230/400 V markets. More configurations are available; metered models offer RS-232 ports for an SNMP card and operate at 0–45 °C.
Applications
Server racks, network cabinets, telecom rooms and small data centers that need reliable, simple power distribution to IT equipment.
Common Questions
What is a rack PDU?
A rack PDU is a power strip designed for 19-inch racks that distributes power from the rack feed to servers, switches and storage, usually through IEC C13 and C19 outlets.
Should I choose a 1U or Zero-U PDU?
1U horizontal PDUs suit small racks with few devices; Zero-U vertical PDUs mount at the back or side of the rack, save rack space and provide more outlets.
Related Products and Guides
- Delta ViLink smart rack PDU – metered and switched PDUs
- Delta data center PDU – floor-standing PDU up to 950 kVA
- Indoor cabinets – racks and power cabinets
Buy the Delta ViFlow rack PDU in Egypt
KPS supplies, installs and supports this equipment across Egypt, including system design, integration and commissioning. Request a quote and our engineers will confirm the right configuration for your site.