KPS engineers solar power systems for Zone 1 and Zone 2 hazardous areas in Egypt, using ATEX/IECEx-certified solar modules, flameproof enclosures and long-life OPzV batteries. These systems power remote monitoring, control and communication equipment on oil & gas sites, unattended, without exposing people or equipment to ignition risk.
Authorized BARTEC and EnerSys distributor in Egypt · ISO 9001, 14001, 45001 and 50001 certified · 250+ projects delivered · 300+ clients served
System architecture
| Stage | Component | Brand | Hazardous-area protection |
|---|---|---|---|
| Generation | SPEX solar modules | Pharos Marine | ATEX Zone 1 certified PV module |
| Conversion | SmartSolar MPPT charge controllers | Victron Energy | Installed in Ex d enclosure, IP66, T5 |
| Storage | PowerSafe OPzV gel battery bank | EnerSys | Zone 1/2 certified battery boxes |
| Monitoring | Cerbo GX with GX IO-Extender | Victron Energy | Installed in certified enclosure |
| Protection | Central power hub with DC MCCB/MCB assembly | BARTEC | Ex d flameproof enclosure, IP66, T5 |

Pharos Marine hazardous-area solar
Pharos Marine Automatic Power builds solar modules and battery enclosures for offshore and hazardous locations. KPS uses SPEX modules certified for Zone 1 and stainless-steel battery boxes for Zone 1 and Zone 2, so generation and storage stay compliant on site.
Victron Energy MPPT and Cerbo GX monitoring
Victron SmartSolar MPPT controllers regulate charging from the solar field, while a Cerbo GX with GX IO-Extender continuously evaluates critical functions and raises alarms remotely. Each controller is housed in a certified Ex d enclosure, and the architecture is split so a single fault never takes the whole system down.
Project example: Zone 1 solar for an oil & gas site
On a site classified Zone 1 for hydrogen hazard, KPS engineered and deployed a solar power system designed to run unattended. It combines a Pharos Marine SPEX solar field, Victron MPPT controllers in Ex d enclosures, an EnerSys OPzV battery bank and a BARTEC central protection hub, with remote visibility from day one. Read the full oil & gas case.
Zone 0, Zone 1 and Zone 2 at a glance
| Zone (gas) | Explosive atmosphere present | Typical solar approach |
|---|---|---|
| Zone 0 | Continuously or for long periods | Avoid locating power equipment here |
| Zone 1 | Likely in normal operation | Zone 1 certified modules, Ex d enclosures, certified battery boxes |
| Zone 2 | Not likely, and only briefly if it occurs | Zone 2 or Zone 1 certified equipment |
For equipment selection across zones, see our ATEX and explosion-proof equipment page.
Hazardous-area solar: FAQs
Can solar panels be installed in a Zone 1 hazardous area?
Yes, if every component is certified for the zone and gas group. KPS uses ATEX/IECEx-certified Pharos Marine SPEX solar modules and houses non-certified electronics in certified Ex d flameproof enclosures.
Do you supply Pharos Marine products in Egypt?
Yes. KPS supplies and integrates Pharos Marine hazardous-area solar modules and Zone 1/2 battery boxes in Egypt as part of engineered solar power systems.
How are Victron charge controllers used in Zone 1?
Victron SmartSolar MPPT controllers are not certified for hazardous areas on their own. In KPS systems they are installed inside cast-aluminium Ex d (flameproof) enclosures rated IP66 and T5, certified for the zone.
Which battery is used in a hazardous-area solar system?
KPS typically uses EnerSys PowerSafe OPzV tubular gel batteries for their long life, deep-cycle performance and no water addition, installed in certified battery enclosures.
Is KPS ATEX certified?
The ATEX/IECEx certification applies to the products. KPS supplies and integrates compliant hazardous-area solutions built from globally certified manufacturers and products, such as Pharos Marine and BARTEC.
Power a remote hazardous-area site
Share the zone classification, gas group, load and site location, and a KPS engineer will propose a certified solar power system.